product

Factory Cheap Hot Antibiotics residue test - HoneyGuard Tetracyclines Test Kit – kwinbon

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our pursuit and firm aim should be to "Always fulfill our buyer requirements". We carry on to produce and structure top-quality excellent solutions for equally our aged and new consumers and accomplish a win-win prospect for our consumers as well as us for Cheese Test Kit , Serum Test Kit , ASFV Rapid Test , As an expert specialized within this field, we've been committed to solving any problem of high temperature protection for users.
Factory Cheap Hot Antibiotics residue test - HoneyGuard Tetracyclines Test Kit – kwinbon Detail:

Cat. KB01009K-50T

About
This kit is used for rapid qualitative analysis of tetracyclines in honey sample.

Sample prepare method
(1) If the honey sample crystallized ,warm it in water bath not high than 60℃, till the honey sample thaw ,mix completely ,cooling as room temperature , then weight for assay.
(2) Weigh 1.0±0.05g homogenate into a 10ml polystyrene centrifuge tube, add 3ml sample extraction solution, vortex for 2min or shake it by hand until the sample is mixed completely.

Assay operations.
(1.) Take bottles needed from the kit package, take out required cards, and make proper marks. Please use these test cards within 1h after open package.
(2.) Take 100l prepared sample into the sample hole by pipette, then start the timer after liquid flow.
(3.) Incubate for 10min at room temperature.
7.LOD

Tetracyclines

LOD(μg/L)

Tetracyclines

LOD(μg/L)

tetracycline

10

doxycycline 15
aureomycin

20

oxytetracycline

10

Results
There are 2 lines in the card result area, Control line and Tetracylcines Line, which are briefly  sed as “B” and “T”. The test results will depend on the color of these lines. The following diagram describes the result identification.
Negative: Control line and Test line both are red and T Line is darker than the control line;
Tetracyclines Positive: Control Line is red, T Line has no color or T Line is lighter color than C line, or the T Line is the same as C Line.

Results

Storage
2-30°C in dark dry place, do not freeze. The kit will be valid in 12 months. The lot number and expired date are printed on the package.


Product detail pictures:

Factory Cheap Hot Antibiotics residue test - HoneyGuard Tetracyclines Test Kit – kwinbon detail pictures

Factory Cheap Hot Antibiotics residue test - HoneyGuard Tetracyclines Test Kit – kwinbon detail pictures

Factory Cheap Hot Antibiotics residue test - HoneyGuard Tetracyclines Test Kit – kwinbon detail pictures


Related Product Guide:

We not only will try our greatest to present fantastic expert services to each purchaser, but also are ready to receive any suggestion offered by our prospects for Factory Cheap Hot Antibiotics residue test - HoneyGuard Tetracyclines Test Kit – kwinbon , The product will supply to all over the world, such as: UAE, Casablanca, Singapore, The credibility is the priority, and the service is the vitality. We promise we have now the ability to offer excellent quality and reasonable price items for customers. With us, your safety is guaranteed.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Cornelia from Portugal - 2017.02.28 14:19
    The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Arthur from Nicaragua - 2018.06.05 13:10
    Write your message here and send it to us