High definition Sulfonamide residue test kit - HoneyGuard Tetracyclines Test Kit – kwinbon
High definition Sulfonamide residue test kit - HoneyGuard Tetracyclines Test Kit – kwinbon Detail:
Cat. KB01009K-50T
About
This kit is used for rapid qualitative analysis of tetracyclines in honey sample.
Sample prepare method
(1) If the honey sample crystallized ,warm it in water bath not high than 60℃, till the honey sample thaw ,mix completely ,cooling as room temperature , then weight for assay.
(2) Weigh 1.0±0.05g homogenate into a 10ml polystyrene centrifuge tube, add 3ml sample extraction solution, vortex for 2min or shake it by hand until the sample is mixed completely.
Assay operations.
(1.) Take bottles needed from the kit package, take out required cards, and make proper marks. Please use these test cards within 1h after open package.
(2.) Take 100l prepared sample into the sample hole by pipette, then start the timer after liquid flow.
(3.) Incubate for 10min at room temperature.
7.LOD
Tetracyclines |
LOD(μg/L) |
Tetracyclines |
LOD(μg/L) |
tetracycline |
10 |
doxycycline | 15 |
aureomycin |
20 |
oxytetracycline |
10 |
Results
There are 2 lines in the card result area, Control line and Tetracylcines Line, which are briefly sed as “B” and “T”. The test results will depend on the color of these lines. The following diagram describes the result identification.
Negative: Control line and Test line both are red and T Line is darker than the control line;
Tetracyclines Positive: Control Line is red, T Line has no color or T Line is lighter color than C line, or the T Line is the same as C Line.
Storage
2-30°C in dark dry place, do not freeze. The kit will be valid in 12 months. The lot number and expired date are printed on the package.
Product detail pictures:
Related Product Guide:
We have a highly efficient team to deal with inquiries from customers. Our goal is "100% customer satisfaction by our product quality, price & our team service" and enjoy a good reputation among clients. With many factories, we can provide a wide range of High definition Sulfonamide residue test kit - HoneyGuard Tetracyclines Test Kit – kwinbon , The product will supply to all over the world, such as: Netherlands, Ghana, New Zealand, Based on products and solutions with high quality, competitive price, and our full range service, we have accumulated experienced strength and experience, and we've built up a very good reputation in the field. Along with the continuous development, we commit ourselves not only to the Chinese domestic business but also the international market. May you moved by our high quality items and passionate service. Let's open a new chapter of mutual benefit and double win.
By Miguel from Saudi Arabia - 2017.08.18 18:38
The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.
By Eunice from Estonia - 2017.11.11 11:41